Chlorinated water dosing pump selection

Email: sales01@cxflowmeter.com
whatsapp: 008618049841995

 
Today we met a customer who needed to consult how to choose a chlorinated dosing pump. He provided the following information and specific requirements:
 
Medium: Chlorinated water
Total suspended solids: 4.4mg/L
Total dissolved solids: 7289mg/L
Chlorine content: 2969mg/L
Hydrogen energy: 6.4ph
Relative density (at 20C): 1.04477
Flow range: 5500 BWPD
Pressure: 750psi
Temperature: 100-130 degrees Fahrenheit
Viscosity: 0.58 to 0.77 cP
Pressure: 0.94/2.2 psi
Pump API 610 12th Edition
Performance test sealing system API 682
NPSH test lubricating oil system API 614
Disassembly (peel test) flange end connection ASME B16.5
Dye penetrant inspection - impeller face-to-face size ASME B16.10
Casing ASTM A182 Gr F53
Impeller ASTM A890 Gr 5A
Casing wear ring UNS S 32760
Shaft ASTM A276
Sleeve TBC*
Interstage bushing UNS S 32760
Mechanical seal flange TBC*
Bearing bracket ASTM A216 WCB
Base plate ASTM A 36
Mechanical seal spring ASTM C276 / C4 / C22
Mechanical seal other metal parts ASTM 316 SS
Mechanical seal wetted parts INCONEL 625 / SDS
Manufacturer drawings and documents. Required
Assembled unit
O&M instructions
Cross-section view Mechanical seal drawing
Pump data sheet
Certification test curve instructions Wiring diagram Speed ​​torque curve
Cold alignment curve data L & T vibration analysis Bill of materials
 
The motor nameplate rating shall be at least 110% of the pump rated power.
2) The pump shall have a continuous head rise from the rated point to the shut-off point with the head rise not less than 10% of the rated head.
3) The capacity at the end of the curve shall not be less than 120% of the rated capacity
4) The minimum continuous stable capacity shall not exceed 50% of the rated capacity.
5) The preferred working area of ​​the pump should be 70% to 120% of the best efficiency flow of the provided pump.
 
After careful analysis by our technicians, we recommended a three-plunger high-pressure reciprocating pump with the following parameters for him

 
1. Three-plunger high-pressure reciprocating pump
1. Pump model and name: three-plunger high-pressure reciprocating pump
2. Parameters: Inlet pressure: Pin>0.1Mpa; Outlet pressure: Pout=5.0Mpa
Flow rate: Q=36M³/H (600L/min)
3. Model: 3DP130 (rated plunger thrust 7.8T)
4. Stroke: S=130mm
5. Plunger diameter: D=100mm (actual plunger thrust on crankshaft 4.4056T)
6. Pump speed: n=205r/min (volume coefficient 0.95)
7. Motor: N axis=63.4371kw; Matching: Y2-280S-4; 75KW-4 ordinary motor; 1460r/min;
8. Hard gear reducer deceleration, ZDY250-7.1, reduction ratio 1:7.1
9. Assembly form: fixed
10. Lubrication method: splashing
11. Material of flow element: 2507, zirconium oxide ceramic plunger
12. Liquid inlet form: pipe diameter DN150, liquid outlet form: pipe diameter DN125
 
If you are also troubled by the selection of chlorine-containing water pumps and don’t know how to choose a suitable industrial pump,
please consult CIXIFM winny. We will have professional technical engineers to recommend the most suitable product model for you:
Email: sales01@cxflowmeter.com
whatsapp: 008618049841995


 

Last:Refrigerant magnetic pump selec.. Next:How to choose a Coriolis flow m..

Contact Us

Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

Phone:021-57635022

E-mail:info@gnflowmeter.com

E-mail:sales@gninstruments.com

關閉
主站蜘蛛池模板: 常德市| 宜昌市| 遂平县| 澎湖县| 固安县| 霍林郭勒市| 钟祥市| 新民市| 广宗县| 迁安市| 恩平市| 漳州市| 大足县| 绍兴市| 行唐县| 大宁县| 巴马| 新乡县| 尼木县| 曲阜市| 遂溪县| 黎城县| 慈利县| 聂荣县| 茌平县| 江陵县| 灵山县| 沂水县| 肇东市| 霍州市| 荔波县| 永德县| 景德镇市| 盐城市| 海南省| 嘉义县| 湄潭县| 象州县| 满洲里市| 林口县| 昌吉市|