玖玖成人,国产精品成人爰爱在线,国产大陆一区二区三区,亚洲精品综合欧美二区变态,伊人伊成久久人综合网,1024欧美一区二区日韩人妻,99国产欧美久久久精品密桃,92久久偷偷做嫩草影院免费看

sales@gninstruments.com

Type:explosion-proof thermal resistance2

Illustrate: It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from -200℃ to 500℃ with exploxives such as hydrocarbon on production spot.

Explosion-proof Thermal Resistance

 

Application 
It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from -200℃ to 500℃ with exploxives such as hydrocarbon on production spot.
 
Features
Spring thermal element with good shock-proof performance;
High measuring accuracy;
No compensational wire, spare cost;
Imported film resistor with high reliability and stability

 
Operation Theory
Explosion-proof thermal resistance has a junction box of enough strength with gaps inside it. All spare parts which might produce spark, electric arc, and dangerous high temperature are sealed in the junction box. When explosion within the box happens, fire and high temperature caused by explosion could be extincted and cooled. Thus, explosion separation could be realized.
 
Main Technical Parameters
Executive Standard
IEC751
JB/T8622-1997
JB/T8623-1997
JB/T5518-1991
 
Insulation Resistance at Normal Temperature
The insulation resistance between electrode and protection tube of the thermocouple shall be no less than 100 MΩ under condition that environment temperature is 15~35℃, relative humidity is no more than 80%, and testing voltage is D.C.10~100V.
 
Measuring Range & Tolerance


Type  Graduation Measuring Range ℃ Accuracy  Tolerance
WZP Pt100 -200~+500 A ±(0.15+0.002) ltl
WZC Cu50  
Cu100
-50~+100 B ±(0.30+0.005) ltl
--- ±(0.30+0.005) ltl
 
Remarks: t is absolute value actually tested with thermal sensor.

Certificates List

Explosion-proof Class Certificate No. Certifying institution 
d ⅡBT4 GYB96451 NEPSI
d ⅡBT4 GYB96452 NEPSI
d ⅡCT5 GYB98338 NEPSI
d ⅡCT5 GYB97178 NEPSI
iaⅡCT6 GYB99413 NEPSI
 
Remarks: NEPSI National Explosion-Proof Security Inspection 
 
Indication of Explosion-proof Function

d      Ⅱ      □     T□        
         Temperature Group: T1-T6  
  Explosion-proof Class: A, B, C
     Electric Equipment for plant 
       Explosion Separation Type 
        Intrinsic Safety Type   
 
Electric Equipment Category

I –Electric Equipment for Coal Mine Well 
II –Electric Equipment for Plant
Explosion-proof Class
It is divided into Class A, B, and C according to maximum test safety gap in explosive gas compound.

Category Class Max.Test Safety Gap
A 0.9≤MESG
B 0.5<MESG<0.9
C MESG≤0.5
 
Temperature Group
It includes T1-T6 according to maximum surface temperature allowed of open part.

Temperature Group Max. Surface Temperature Allowed
T1 450
T2 300
T3 200
T4 135
T5 100
T6 85
 
Junction Box Figure 
 
Class d II BT                        Class d II CT
Terminal Figure

Type Naming Method

W Temperature Instrument
  z Thermal Resistance
    Thermal Element Material
P P Pt
C C Cu
   
 
Filament
blank Simplex  
2 Duplex
 
 
Mounting &fixing
1 Without fixing device
2 Threaded connector
3 Movable Flange
4 Fixed flange
5 Elbow tube connector
6 Fixed threaded Cone connector
7 Straight tube connector
8 Fixed threaded tube connector
9 Movable threaded tube connector
  Junction box
4 Explosion-proof Type
 
 
Protection Tube Diameter
    0Φ16
  1Φ12
  Measuring End 
G Variable cross section
W Z P 2 2 4 1 G Model example

Last:thermal resistance with threade.. Next:Without the